6·19
ELECTRICAL SYSTEM
Check the electrolyte level and add distilled
water,
as necessary,
to raise
the electrolyte to each cell's
MAX. level.
Check the battery for
proper
charge by taking an
electrolyte S.G.
reading. If
the
reading is
1.22 or
less, as corrected to 20°C,
it
means that the battery
is still
in
a discharged condition and needs
re-
charging.
BASED ON S.G. READIN
G
RECHARGING
OPERATION
To correct an S.G. reading
20°
C, use the
table
at
the
right.
To
read the S.G. on the hydrometer, bring the
electrolyte in the hydrometer
CD
to eye level and
read the
graduations on the
float
sca
le
bordering
on
the meniscus (curved-up portion of electrolyte
surface), as shown in figure
.
Check the reading
(as
corrected to 20°C)
with
chart
to
determine the recharging
time
in hours by
constant·current charging at a charging rate of
0
.5
amperes (which is a tenth of
the
capacity of
the
present battery).
Be
careful
not
to permit the electrolyte tempera·
ture to exceed 45°C, at any time, during the
recharging
operation.
I nterrupt the operation, as
necessa
ry,
to let the electrolyte cool down.
Recharge the battery to the specification.
Electrolyte
specific
gravity
CAUTION:
Constant·voltage charging, otherwise
called
"quick" charging,
is not recommended as it
cou
ld
shorten
the life of
the
battery.
09900·28403
Hydrometer
, . 2
9F
::==J
~
1.28
.~
1.27
r-
Norm.
Q,
1.26
{=-~~~~:'f.,.--J
.~
1.25
~
1.24
.
[R-;;ch.
n
~
1.23
"_.
(/)
1.22
-
-
1.21
Recharge or
RfPl'-'t
°c
0 5 10 15
20 25 30 35
40
of 3241
50
5968 11 86 95