6-9
ELECTRICAL
SYSTEM
ACTUATOR PULLEY
When
reinstalling
the pulley to the pulley shaft,
turn
the pulley
shaft and bring the engraved
line
CD
on
the
shaft end to right side by 36
degree
to
the
index
mark
@
on the actuator
body.
Install
the
pulley
to the shaft so that the aligning
mark
@
on the
pulley
meets the
index
mark
@.
NOTE:
When connecting
the exhaust valve control
cables to the
actuator,
make
sure
that
the
pulley should be
kept at the
right
figure
and
arl exhaust valves
shoul
d
be opened.
EXHAUST VALVE
CONTROL
UNIT
Remove
t
he seat and
pillion
seat.
Remove the seat
ta
il cover.
Disco nnect the couplers and remove the
control
unit
CD.
Use a
SUZUKI pocket
tester
(x 25
DCV) and
connect the
~
and
e
probe
pins to
Gray
and
Pink leads
respectively
.
Apply
12V
(DC) to the Orange
Ef)
and
Black/
White
e.
If
the tester shows
8
- 12V for approx.
one
second, control unit is
in
good
condition
about
TIMER circuit and
motor
driving
circuit.
Further
inspection is needed.
Use the Suzuki
pocket tester, bring
the
ffi
probe
and
the
e
probe
into contact with
each
lead wire of the control unit, check for con-
tinuity, and measure the resistance
value.