The appearance of the Optics group box is dependent on whether dual scan,
single scan or dual scan sequential is selected. In dual scan sequential Channel
st
1 1
Run and Channel 1 2
Laser Channel 2.
Laser Channel 1 combo box
Select the appropriate laser from the Laser Channel 1 combo box for excitation.
The selection of lasers is dependent on the type of instrument connected.
Laser Channel 2 combo box
Select the appropriate laser from the Laser Channel 2 combo box for excitation.
The selection of lasers is dependent on the type of instrument connected.
Laser Channel 2 is only activated, if Dual Parallel Scan Mode has been
selected in the General tab.
Filter Channel 1 combo box
Select the appropriate filter from the Filter Channel 1 combo box to match with
the selected excitation wavelength in Laser Channel 1.
All filters that have been defined in the filter slide which is inserted into Filter
Channel 1, can be selected from the Filter Channel 1 combo box.
Filter Channel 2 combo box
Select the appropriate filter from the Filter Channel 2 combo box to match with
the selected excitation wavelength in Laser Channel 2.
All filters that have been defined in the filter slide which is inserted into Filter
Channel 2, can be selected from the Filter Channel 2 combo box.
Filter Channel 2 is only activated, if Dual Parallel Scan Mode has been selected
in the General tab.
PMT Gain Channel 1 edit box
Set PMT Gain to a value between 70 and 255 to regulate the detector sensitivity
in Channel 1.
The PMT Gain can also be adjusted online during the measurement via the
Status control dialog box window. The Status dialog box is displayed after
clicking the Start button.
PMT Gain Channel 2 edit box
Set PMT Gain to a value between 70 and 255 to regulate the detector sensitivity
in Channel 2.
The PMT Gain can also be adjusted online during the measurement via the
Status control dialog box window. The Status dialog box is displayed after
clicking the Start button.
PMT Gain Channel 2 ("Channel 1 2
selected) is only activated, if the instrument is a Dual Channel Instrument and if
Dual Parallel Scan Mode has been selected in the General tab.
Unusable filter laser excitations are signaled by red exclamation marks.