U
S
NIVERSAL
UBSCRIBER
International Power Conversion
This procedure is provided to assist you when you need to convert the USG power
switch from 115V to 230V (this covers the range of voltage from 200 – 260V).
Procedure
Disconnect the power cord. Retain the cord for future use at the lower voltage (if
1.
you need to convert back to 115V).
Remove the existing 4-amp fuse and jumper clip (on the opposite side from the
2.
fuse). Retain the fuse and jumper clip for future use.
For fuse removal and replacement instructions, go to
page
226.
Install a new 3-amp fuse (provided with the USG) on each side of the holder,
3.
ensuring that the orientation of the fuse is the same as the original fuse.
Reinstall the fuse holder, ensuring that the 230V label is visible through the
4.
window when the fuse holder door is closed.
Install a new power cord (not supplied), with the appropriate male connector for
5.
the receptacle to be used.
Troubleshooting
G
™
ATEWAY
"Replacing the Fuse" on
227
Need help?
Do you have a question about the Universal subscriber gateway and is the answer not in the manual?
Questions and answers