4.8 Setting the Power-on Initialization Values

The power source is shipped with default factory settings when the unit is powered up. The factory
settings are:
Parameter
Voltage
Voltage Range
Frequency
Current limit
Output state
Local / Remote State
It is possible to change the pow
1. Using the IEEE-488, LAN
2. Using the front panel.
To change the power on initializ
1. Set the AC power source output parameters from the front panel as you want to power up th
unit.
2. Save this setting to setup register 0 from the REGISTERS menu.
3. Select the CONFIGURATION menu and move to the POWER ON field.
4. Change the POWER ON field to REG0.
5. This will recall the settings contained in register 0 at power up.
California Instruments
Factory default setting
0.0 Volt
150 Volt Range
60 Hz
Maximum available current for selected V Range.
OFF
Local. Front panel unlocked.
Tab
le 4-3: Factory Default Power on Settings
er on initialization values in one of two ways:
or USB bus interface.
ation values from the front pane
l, proceed as follows:
2253i / 2253iX