California Instruments 2253i User Manual page 151

Ac and dc power source & analyzer
Hide thumbs Also See for 2253i:
Table of Contents

Advertisement

User Manual
Number
Message String
-201
"Invali
-203
"Comm
-210
"Trigger error"
-211
"Trigger ignored"
-213
"Init ignored"
-220
"Parameter error"
-221
"Setting conflict"
-222
"Data out of range"
-223
"Too much data"
-224
"Illegal pa
-226
"Lists not same length"
-241
"Hardware missing"
-254
"Media full"
-255
"Directory full"
-256
"File name
-257
"File name error"
-283
"Illegal variable name"
-300
"Device specific error"
-311
"Memory error"
-314
"Save/recall memory
California Instruments
Cause
d while in local"
Command iss
is not in remote state
and protected"
Command is
Problem with trigger
system.
Trigger request has b
ignored.
Initialization request has
been ignored
Parameter not allowed.
Transient programmed
with more than 1 mode.
Parameter data outside of
allowable range.
More data receiv
expected
rameter value"
Parameter value is not
supported
One or more transient lists
programmed have
different length.
N/A
No storage space left to
save settings or data.
Too many wavef
directory entries
not found"
Waveform requested n
in directory
Incorrect filename
Variable name illegal.
Hardware related er
Waveform memory
checksum error.
User setup register
Remedy
ued but unit
Put instrument in remote state before
issuing GPIB commands.
locked out
Some commands are supported by the
unit but are locked out for protection of
settings and are not user accessible.
Unit could not generate trigger for
transient execution or
een
Trigger setup incorrect or unit was not
armed when trigger was received. Chec
transient system or measurement
system settings.
Unit was told to go to armed st
was unable to do so. Could be caused
incorrect transient system or
measurement acquisition setup.
Incorrect parameter or parameter
Check programming manual for
allowable parameters
Check other settings. E.g. Redefine
transient mode.
As result of *TST? execution, indi
ALC mode i
S
ine.
Check programming manual for
allowable parameter values
ed than
Check programming manual for number
of parameters or data block size
Check programming m
parameters
All lists must be of same length or
transient cannot be compiled and
executed.
N/A
Delete other settings or data to ma
room.
orm
Delete one or more waveforms from
waveform memory to make room.
ot
Check waveform directory for waveform
names present.
Too many or non-ASCII characters used
in waveform file definition.
Use ASCII characters only
ror
Check hardware for proper operation.
May be the result of incomplete user-
defined waveform download. Check
interface and try downloading waveform
again. Successful download may clear
this error condition.
Alternatively, use TRAC:DEL:ALL
command to clear waveform me
Store setup in same register again
2253i / 2253iX
measurement.
trigger
ate but
value.
cates
s off or waveform not set to
anual for correct
ke
mory.
.
k
by
151