User Manual
2.12 Supplemental Specifications
Supplemental specifications are provided for reference only and are not guaranteed. Data is based on
typical performance of a Compact i/iX series power source but not verified on each unit produced as
part of California Instruments acceptance test.
Results on individual units may vary from the data provided here.
2.12.1 Output
Output Parameter
Frequency response:
Max. Voltage slew:
Load Transient response
No load to full load:
Full load to no load:
Load Regulation response in
ALC mode
Load Regulation:
(ALC mode OFF)
1
FS (Full Scale) refers to highest available range, e.g. 300Vac in AC mode, 400Vdc in DC mode.
California Instruments
Specification
4V/us, measured step response into resistive load, 10% to 90 % full-
Voltage recovers to within 2% in less than 2 ms
Voltage recovers to within 2% in less than 2 ms
Figure 2-8: Typical frequency response, low Vrange, ALC off.
Figure 2-8
See
scale voltage.
< 300 ms
1
< 3 % FS
2253i / 2253iX
31