User Manual
4.2.4 PROGRAM Menu
The PROGRAM menu is s
1. By selecting the MENU
2
. By pressing
The PROGRAM menu is u
are located in the CONTROL menu.
T
he following c
ENTRY
VOLTAGE
FREQ
VRANGE
PHASE
FUNC
California Instruments

Figure 4-5: PROGRAM Menu

hown in Figure 4-5. It can be reached in one of two ways:
key, selecting the PROGRAM entry and pressing the
the SET k
ey.
sed to change primary output parameters. Less frequently use
hoices are
available in the PROGRAM menus:
DESCRIPTION
Programs the output voltage in Vrms. The voltage can be
changed from 0 to its max range value as determined by the
configuration settings and the selected voltage range using
keypad + Enter or the shuttle (if the voltage field is selected)
NOTE: Voltage programmin
three output phases at the same time, use the PHASE key first
to select coupled mode (A, B, C phase indicator all on). To
program an individual phase only, select the desired phase
using the PHASE key first.
Programs the output frequency. The frequency can be change
from it
s min to its max value as determined by the configuration
settings using the keypad + Enter or the shuttle (if the frequen
field is selected).
Selects 150V or 300V voltage range (if available). The actual
range values may be different depending on the configuration.
The value of this field can be changed with the shuttle as long
as the active pointer ( ) points to the VRANGE entry. If only
one voltage range is available, this field cannot be changed.
Selects the phase angle between the external clock and the
output of the AC source. If the clock source is internal, this
parameter has no effect. Th
only, regardless of the phase selection in effect.
Selects the waveform for the selected phase. On iX models,
available choices are SINUSOID, SQUARE and CLIPPED or
any user defined waveform that was downloaded to the AC
source waveform memory using one of the available interfaces
This field is fixed to SINUSOID on 'i' models.
NOTE: Function programming is phase specific. To program all
three output phases at the same time, use the PHASE key first
to select coupled mode (A, B, C phase indicator all on). To
program an individual phase only, select the desired phase
g is phase specific. To program all
is setting always applies to phase A
2253i / 2253iX
Enter key.
d parameters
the
.
d
cy
.
59