Amplifier Module Data - California Instruments 2253i User Manual

Ac and dc power source & analyzer
Hide thumbs Also See for 2253i:
Table of Contents

Advertisement

User Manual

7.6 Amplifier Module Data

This section lists the various connectors and interface pin outs to the 6005-400-1 amplifier module.
7.6.1 CONTROL BOARD
7.6.1.1
J1 -
LV POWE
PINS
1,2,3
4,5,6
7,8
9,10
11,12
13,14
15,16
7.6.1.2 J5 - FAN
PINS
1
2
7.6.1.3 J6 - E/A IN/OUT
PINS
1
2
7.6.1.4 J2 - CONTROL SIGNALS
PINS
1
2
3
4
5
6
7
8
9
10
California Instruments
R
NAME
DESCRIPTION
+24V_FAN
+12.0 Vdc to +24.0 Vdc @ 200 mAdc for module fan. Voltage is
externally contro
FAN_COM
Return for +24V_FAN
+15G
+15 Vdc +/- 0.5Vdc @ 450 mAdc for gate drive
G_COM
Return for +15G
+15LV
+15 Vdc +/- 0.5V
LV_COM
Return for +15LV and –15LV
-15_LV
-15Vdc +/-0.5Vdc @ 100 mAdc for control circuits
NAME
DESCRIPTION
FAN_COM
Return for fan
+24V_FAN
DC voltage for fan
NAME
DESCRIPTION
E/A COM
Return for E/A IN/OUT
E/A IN/OUT
Error amplifier signal from master module to parallel auxiliary
modules
NAME
DESCRIPTION
A_COM
Analog common
A_SIG_
HI
Phase A oscillator signal, 16 Hz to 1 kHz, 0 –
B_SIG_
HI
Phase B oscillator signal, values same as A_SIG
C_SIG_
HI
Phase C oscillator signal, values same as A_SIG
SCOM
Signal common for A/B/C_SIG_HI
DCOM
Digital logic common
LO_RN
G
Low Range control signal, input to module, TTL
Voltage Range, TTL HI = High Voltage Range
/AMP_FLT
Amplifier fault indicator signal, output from module, open
collector, LO = blown fuse fault detected, HI = normal
PARALLEL
One phase (parallel) / Three phase mode control signal, LO =
three phase mode, HI = one phase mode.
/OVT
Overtemperature fault indicator signal, output from module, open
collector, LO = Over temp fault detected, HI = normal
lled according to output current.
dc @ 150 mAdc for control circuits
2253i / 2253iX
5.3 Vac
_HI
_HI
LO = Low
102