Table 9-18: Abnormal Voltage Surge - California Instruments 2253i User Manual

Ac and dc power source & analyzer
Hide thumbs Also See for 2253i:
Table of Contents

Advertisement

User Manual
VOLT SURGE
This test will produce voltage surge defined by Table 9-18. This test will be repeated three times with
ten second
s intervals. The voltage values are halved for 14.0V category B equipment.
Category
A
B
Z
9.6.3 E
mergency Test
The Emergency test is selected from the DO-160 DC Main Menu. This test will set the output voltage
to 18V for 28V equipment and to 9V for 14V equipment. The test will last for 30 minutes. The
(backspace) will terminate the test at any time.
California Instruments
Surge 1
Volt
Dwell (msec)
46.3
100
60
100
80
100

Table 9-18: Abnormal Voltage Surge

Surge 2
Volt
Dwell (msec)
37.8
1000
40
1000
48
1000
2253i / 2253iX