10.6 AC Test Mode

Following sections cover testing in AC output mode.
10.6.1 Steady State Tests
Scroll to the STEADY STATE entry using the up and down cursor keys. Press the ENTER key to
select the STEADY STATE screens. The screen will appear as shown in Figure 10-3
The MIL704 Steady state screens have the following tests:
1. VOLTAGE
2. FREQUENCY
3. VOLT UNBALA
4. PHASE DIFFERENCE
5. VOLT MODULATIO
6. FREQ MODULATION
7. VOLT TRANSIENT
8. FREQ TRANSIENT
9. DISTORTION
The above tests can be selected by scrolling to the highlighted selection using the up and down cursor
keys and the ENTER key to start the selected test.
VOLTAGE
This test will change the output voltage in the sequence shown in Table 10-1.
SEQUENCE
The
key (backspace) will termina
California Instruments
Figure 10-3: Steady State M
NCE
N
VOLTAGE
400Hz/VFREQ
1
108
2
118
3
115

Table 10-1: Steady state voltage

te the
enu
TIME
60Hz only
110
1 minute
125
1 minute
115
1 minute
te
st at any time.