Air Cleaner Element Installation - Isuzu NHR 4J Series Workshop Manual

Table of Contents

Advertisement

Carbon and Dust Fouled Element
1. Prepare a cleaning solution of Isuzu Genuine Element
Cleaner (Donaldson D1400) diluted with water.
2. Submerge the element in the solution for twenty
minutes.
6C-64-1.tif
3. Remove the element from the solution and rinse it well
with running water.
Water pressure must not exceed 274 Kpa
(2.8 kg/cm
6C-64-2.tif
4.
Dry the element in a well ventilated area.
An electric fan will hasten drying.
NOTE:
Do not use compressed air or an open flame to dry the
element quickly. Damage to the element will result. It
will usually take two or three days for the element to
dry completely. Therefore, it is a good idea to have a
spare on hand to use in the interim.
6C-64-3.tif
INSTALLATION
4. Air Cleaner Element
3. Filter Wing Nut
2.
End Cover
1. Cover Wing Nut
ENGINE FUEL 6C - 65
2
/40 psi).