Platen Speed Fine Adjustment Mode - TEC CB-416 Series Maintenance Manual

Color printer
Table of Contents

Advertisement

5. DIAG. TEST OPERATION
5.3.6

Platen Speed Fine Adjustment Mode

If a color misalignment occurs due to paper thickness, elasticity, slack, etc., change the platen
speed to prevent the color misalignment.
NOTES:
1. This operation is effective when "AUTO" is selected in Section 5.3.5.4 Pulse
2. If a color misalignment occurs even after the platen speed fine adjustment, select
3. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds
4. Max. fine adjustment – 60 steps = Platen speed fine adjustment value.
5. A changed motor voltage value is stored in memory by pressing the [PAUSE]
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
>
D I A G .
Press the [FEED] key.
< 2
>
P A R A M E T E R
Press the [PAUSE] key.
P O
S
I T I O N
Press the [FEED] key five time.
P M
A D J .
Press [PAUSE] key.
P M
A D J .
Press the [FEED] or
[RESTART] key to fine
adjust the platen motor
voltage. (See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Motor Speed Selection.
"104" for the pulse motor speed in Section 5.3.5.4 Pulse Motor Speed Selection.
enables a fast forward.
key.
V 1 . O A
S E T
Platen speed fine adjustment display
+ 0
[FEED] key:
[RESTART] key: pressing the [RESTART] key
Press the [PAUSE] key.
5-38
EO18-33002A
(Revision Date: Dec. 20, 2000)
5.3 PARAMETER SETTING MODE
pressing the [FEED] key one
time is a -1 step change, up to
-60 steps. (See NOTE 2.)
one time is a +1 step change,
up to +60 steps.
(See NOTE 2.)
+ : Slower
— : Faster

Advertisement

Table of Contents
loading

This manual is also suitable for:

426-t3 seriesCb-416-t3 seriesCb-426-t3 series