8.42 Touch Panel ASSY/LCD
(1) Remove the three Taptite cup B 3x10 screws. Release the twelve Hooks to remove the
LCD hold plate from the Control panel ASSY.
LCD hold plate
Hook
Hook
(2) Remove the LCD from the Control panel ASSY.
(3) Disconnect the Flat cable from the Connector (CN1) of the Key PCB ASSY.
Remove the Touch panel ASSY.
Touch panel ASSY
Control panel ASSY
Taptite cup B 3x10
Hook
Hook
Fig. 3-138
LCD
Fig. 3-139
3-103
Hook
Control panel ASSY
CN1
Taptite cup B 3x10
Hook
Flat cable
Key PCB ASSY
Confidential