- Clean the corona wire of each drum unit for all four colors.
- Replace the drum unit with a new one and reset the drum counter.
Step
1
2
3
4.7.5
Drum unit replacement
(Even though drum counter is reset, "Replace Drum" warning remains.)
Step
1
2
3
Cause
Dirt on the GRID electrodes of
the drum unit
High-voltage power supply
PCB failure
Main PCB failure
Cause
Dirt on the GRID electrodes of
the drum unit
High-voltage power supply
PCB failure
Main PCB failure
Clean the GRID electrodes of the main body
and the drum unit.
(Refer to
fig. 2-7 (P2-50)
Replace the high-voltage power supply PCB
ASSY.
Replace the main PCB ASSY.
Clean the GRID electrodes of the main body
and the drum unit.
(Refer to
fig. 2-7 (P2-50)
Replace the high-voltage power supply PCB
ASSY.
Replace the main PCB ASSY.
2-108
Remedy
and
fig. 2-8
(P2-51))
Remedy
and
fig. 2-8
(P2-51))