■ Error code 0501
Print Unable 05
Turn the power off and then back on again.
The center thermistor of the fuser unit does not reach the specified temperature within the
specified time.
Error code 0502
Print Unable 05
Turn the power off and then back on again.
The center thermistor of the fuser unit does not reach the specified temperature within the
specified time.
Error code 0503
Print Unable 05
Turn the power off and then back on again.
The center thermistor of the fuser unit detected a temperature higher than the specified value.
Error code 0504
Print Unable 05
Turn the power off and then back on again.
After the center thermistor of the fuser unit was normally heated, it detected a temperature
lower than the specified value.
Error code 0505
Print Unable 05
Turn the power off and then back on again.
The center thermistor of the fuser unit detected a temperature rise greater than the specified
value within a set period of time.
Error code 0506
Print Unable 05
Turn the power off and then back on again.
The center thermistor of the fuser unit detected a temperature fall greater than the specified
value within a set period of time.
<User Check>
- Turn the power OFF and ON again after several seconds to check if the error code
disappears.
Step
1
Connection failure of the center
or side thermistor harness of the
fuser unit
2
Connection failure of the heater
harness of the fuser unit
3
Harness connection failure of the
eject sensor PCB
4
Harness connection failure of the
low-voltage power supply PCB
5
Eject sensor PCB failure
6
Fuser unit failure
7
Low-voltage power supply PCB
failure
8
Main PCB failure
Cause
2-35
Remedy
Check the harness connection of the
center or side thermistor of the fuser unit
and reconnect them.
Check the harness connection of the
heater of the fuser unit and reconnect it.
Check the harness connection of the eject
sensor PCB and reconnect it.
Check the harness connection of the
low-voltage power supply PCB and
reconnect it.
Replace the eject sensor PCB ASSY.
Replace the fuser unit.
Replace the low-voltage power supply
PCB ASSY.
Replace the main PCB ASSY.