Assembling Note:
Since the Second side CIS flat cable might be broken when you remove it from the Flat cable
holder ASSY, be sure to replace it with a new Second side CIS flat cable. When assembling
a new Second side CIS flat cable, be sure to assemble it in accordance with the following
procedure.
< Assembling procedure >
(1) Fold the Second side CIS flat cable at the Second side CIS unit side as shown in the
how-to-fold figure below.
Supporting tape
(90 mm: Tape width)
(2) Mount the Second side CIS flat cable at the Second side CIS unit side to the Second side
CIS unit.
Second side CIS flat cable
Fold down FFC along with the solid line
Fold up FFC along with the dotted line
Second side CIS flat cable
45°
Fig. 3-66
Second side CIS unit
Fig. 3-67
3-64
Supporting plate
(7±1.5 mm)
(89 mm)
(13 mm)
17±1 mm
Confidential