Brother MFC-9130CW Service Manual page 61

Color fax/mfc
Hide thumbs Also See for MFC-9130CW:
Table of Contents

Advertisement

Error
Problem
codes
AD00
First side scanned data cannot
be output with the required
number of pixels, and image
processing cannot be completed
successfully.
AF00
The first side CIS fails to move,
remaining at the home position.
B000
The first or second side CIS flat
cable was detected to be not
inserted correctly.
B300
---
B400
---
B700
During scanning, obtained
voltage was above the upper
limit.
B800
During scanning, obtained
voltage was below the lower
limit.
B900
During scanning, obtained white
level does not increase though
light intensity is increased.
BA00
---
BB00
The white level value obtained
with function code 55 was
outside the specified range.
BC00
Though a fax was scanned again
after AC00 error, the second side
white or black calibration data
was not within the normal range.
BD00
The black level value obtained
with function code 55 was
outside the specified range.
BE00
---
Refer
Error
to:
codes
2-74
BF00
The first side document scanning
position sensor detected that the
document was 400 mm or more
in length and could not be fed
from the ADF in duplex feeding.
2-74
C001
Timeout occurred with access
request sent to server due to
incorrect server address,
network disconnection, or
2-74
inactive server.
C002
User authentication is
unavailable due to incorrect user
name, incorrect password, or
asynchronous date and time
between the machine and server.
2-75
C003
Access to a file is unavailable
due to incorrect directory name,
no write permission on directory,
file write lock, or no write
2-75
permission on file.
C004
The current time necessary for
user authentication is
2-75
unavailable due to machine
clock (RTC) not being set and
time not being obtained through
SNTP.
C700
The memory is insufficient to
expand the data of PC-Print.
2-75
C800
The memory used to store
secure print data exceeded the
memory size for secure print
data.
2-75
C900
---
CA00
---
2-75
D100
An error occurred during modem
initialization.
D200
The machine detected that the
modem PCB was disconnected.
D800
An error occurred during touch
panel initialization.
2-22
Problem
Confidential
Refer
to:
2-76
2-77
2-77
2-77
2-77
2-78
2-78
2-78
2-78
2-79

Advertisement

Table of Contents
loading