4.14 Others Problems
4.14.1 The machine is not turned ON
<User Check>
- Properly insert the AC cord.
Step
1
2
3
4
5
6
7
4.14.2 Main fan not rotate
Step
1
2
3
4
5
6
7
4.14.3 Main motor failure
Step
1
2
3
4
Cause
Harness connection failure of
the panel PCB
Harness connection failure of
the LCD
Harness connection failure of
the low-voltage power supply
PCB
Panel PCB failure
LCD failure
Low-voltage power supply
PCB failure
Main PCB failure
Cause
Harness connection failure of
the main fan
Harness connection failure of
the high-voltage power supply
PCB
Harness connection failure of
the low-voltage power supply
PCB
Main fan failure
High-voltage power supply
PCB failure
Low-voltage power supply
PCB failure
Main PCB failure
Cause
Flat cable connection failure
of the main motor
Main motor failure
Low-voltage power supply
PCB failure
Main PCB failure
Check the panel PCB harness connection
and reconnect it.
Check the LCD harness connection and
reconnect it.
Check the low-voltage power supply PCB
harness connection and reconnect it.
Replace the Panel PCB ASSY.
Replace the LCD.
Replace the low-voltage power supply PCB
ASSY.
Replace the main PCB ASSY.
Check the harness connection of the main
fan and reconnect it.
Check the high-voltage power supply PCB
harness connection and reconnect it.
Check the harness connection of the
low-voltage power supply PCB and
reconnect it.
Replace the main fan.
Replace the high-voltage power supply PCB
ASSY.
Replace the low-voltage power supply PCB
ASSY.
Replace the main PCB ASSY.
Check the flat cable connection of the main
motor and reconnect it.
Replace the process drive unit.
Replace the low-voltage power supply PCB
ASSY.
Replace the main PCB ASSY.
2-122
Remedy
Remedy
Remedy
Confidential