(4) Disconnect the two Connectors (CN4 and CN5) from the Eject sensor PCB ASSY.
Eject sensor PCB ASSY
(5) Remove the two Taptite pan (washer) B M4x12 DA screws. Remove the Fuser unit from
the Main body holding the "A" parts.
(6) Disconnect the Electrode terminal of the Fuser unit from the Electrode terminal of the
Main body.
6
Hook
Electrode terminal
Connector
Fig. 3-11
5
Electrode terminal
Fig. 3-12
Connector
CN5
CN4
Main body
Fuser unit
"A"
3-34
<Back side>
"A"
<Back side>
Taptite pan (washer)
B M4x12 DA
Confidential