11. Release two hooks and both and then
remove the eject tray.
12. Remove four screws and two connectors
and remove the laser scanner unit.
13. Replace the laser scanner unit and refit all
the removed parts.
Both
Figure 1-5-66
Screw
Screw
Screw
Laser scanner
unit
Connector
Figure 1-5-67
2KJ/2KH
Eject tray
Hook
Hook
Eject tray
Connector
Screw
1-5-39