(4) Detaching and refitting the cassette separation pulley (22 ppm model only)
Follow the procedure below to replace the cassette separation pulley.
Procedure
1. Open the front cover and left cover.
2. Pull out the cassette.
3. Remove the screw and remove the lower
paper feed unit.
4. Release two hooks and remove the separa-
tion pulley unit from the lower paper feed
unit.
Screw
Lower paper feed unit
Figure 1-5-17
Separation pulley unit
Hook
Hook
Lower paper feed unit
Figure 1-5-18
2KJ/2KH
Separation pulley unit
Separation pulley unit
1-5-11