Command reference - xConfiguration
H323 Gatekeeper CallSignaling PortRange End: <1024..65534>
Specifies the upper port in the range to be used by calls once they are established.
Default: 19999
xConfiguration H323 Gatekeeper CallSignaling PortRange End: 19999
Example:
H323 Gatekeeper CallSignaling PortRange Start: <1024..65534>
Specifies the lower port in the range to be used by calls once they are established.
Default: 15000
xConfiguration H323 Gatekeeper CallSignaling PortRange Start: 15000
Example:
H323 Gatekeeper CallSignaling TCP Port: <1024..65534>
Specifies the port that listens for H.323 call signaling.
Default: 1720
xConfiguration H323 Gatekeeper CallSignaling TCP Port: 1720
Example:
H323 Gatekeeper CallTimeToLive: <60..65534>
Specifies the interval (in seconds) at which the VCS polls the endpoints in a call to verify that they are still in the call.
Default: 120
xConfiguration H323 Gatekeeper CallTimeToLive: 120
Example:
H323 Gatekeeper Registration ConflictMode: <Reject/Overwrite>
Determines how the system will behave if an endpoint attempts to register an alias currently registered from another IP address.
Reject: denies the registration.
Overwrite: deletes the original registration and replaces it with the new registration.
Default: Reject
xConfiguration H323 Gatekeeper Registration ConflictMode: Reject
Example:
H323 Gatekeeper Registration UDP Port: <1024..65534>
Specifies the port to be used for H.323 UDP registrations.
Default: 1719
xConfiguration H323 Gatekeeper Registration UDP Port: 1719
Example:
H323 Gatekeeper TimeToLive: <60..65534>
Specifies the interval (in seconds) at which an H.323 endpoint must re-register with the VCS in order to confirm that it is still functioning.
Default: 1800
xConfiguration H323 Gatekeeper TimeToLive: 1800
Example:
Overview and
Introduction
Getting started
status
D14049.05
February 2009
System
VCS
Zones and
configuration
configuration
neighbors
Call
Bandwidth
processing
control
201
TANDBERG
VIDEO COMMUNICATIONS SERVER
Firewall
Applications
Maintenance
traversal
ADMINISTRATOR GUIDE
Appendices

Advertisement

Table of Contents
loading

Table of Contents