NOTE: Terminals #1, #3 and #6 are grounded to key
switch case when key switch is OFF. Meter
must indicate CONTINUITY between these
terminals and the key switch case when key
switch is OFF.
When testing RUN and START terminals, meter
should show CONTINUITY between terminals, with
key switch in position shown.
NOTE: The #2 and #5 terminals should show
CONTINUITY in both the RUN and START
position.
Switch Position
1. OFF
2. RUN
3. START
OFF
1+3+6
Key Switch Positions
3
2
4
1
5
6
OFF
NOTE: TERMINAL 1 GROUNDED IN-
TERNALLY TO SWITCH CASE. METER
MUST ALSO INDICATE CONTINUITY
BETWEEN TERMINAL 1 AND SWITCH
CASE.
Terminal Positions
Fig. 50
54
Continuity
1+3+6
2+5+6
2+4+5
RUN
2+5+6
START
2+4+5
2
3
4
5
1
6
RUN
2
3
4
5
1
6
START