10 Communications
10.9.2. Restore Reporting
For each event group, you can determine whether restore messages will be sent.
To enable or disable restore reporting for an event group:
1.
From the Programming menu, select Communications, Event Options [955].
2.
Select an event group.
3.
From the event group's sub-menu, select Report Restore [#2].
4.
Select Enabled or Disabled.
10.9.3. Two-Way Audio
For Burglary, Fire and Medical event groups, there is an additional option that enables Two-Way Audio for that event
group – see p. 31, 5.2.2 TWA Alarm Reporting.
To enable/disable Two-Way Audio for an event group:
1.
From the Programming menu, select Communications, Event Options [955].
2.
Select an Event Group (Burglary, Fire or Medical).
3.
Select TWA [#3].
4.
Select Enabled or Disabled.
10.10. Vocal Message Dialer Event Options
Events reported using the Vocal Message Dialer are divided into event groups that correspond with the pre-recorded
event messages. This allows you to enable or disable the Vocal Message feature for a specific group of events. For
further information on this feature, see p. 57, 10.3 Vocal Message Dialer.
The vocal message event groups and their associated system events are as follows:
Burglary [#1]
o
Alarm from Zone (excluding Gas
and Environmental zones)
o
Zone Tamper
o
Tamper
o
Duress
Fire [#2]
o
Zone Fire Alarm
o
User Activated Fire Alarm
Panic [#3]
o
Zone Panic Alarm
o
User Activated Panic Alarm
Medical [#4]
o
Zone Medical Alarm
o
Zone Medical Alarm
o
User Activated Alarm
o
No Motion
iConnect
Installation Manual
Arm [#6]
o
Full Arm
o
Part Arm
o
Perimeter Arm
Disarm [#7]
o
Disarm
o
Disarm after Alarm
Water [#8]
o
Zone Water Alarm (Flood)
65