9 System Options
9.3.3.
Supervised Arm
The Supervised Arm option is a feature designed to supervise a wireless device activity before you arm the system. If
the system has not received a transmission from a detector during the interval defined for this option, all arming
methods that include that detector will not be available. Medical, Panic, Fire, Gas, Flood, and Environmental zones are
not included in this supervision and do not affect the system's ability to arm.
Press
to check which detector is causing the "System Not Ready" condition.
To make the required arming method available, activate the detector. PIR detectors have a three-minute delay between
transmissions.
If activating the detector does not help, there may be a problem with the detector. You can bypass the faulty detector's
zone to allow system arming until the problem is remedied – see p. 21, 4.3 Zone Bypassing/Unbypassing.
Zone bypassing is valid for one arming period only. All bypassed zones are automatically
unbypassed when the system is disarmed.
To program the Supervised Arm interval:
1.
From the Programming menu, select System Options, Arm/Disarm, Superv. Arm [94033].
2.
Enter a Supervised Arm interval (001-255 minutes or 000 to disable the Supervised Arm option).
Do not program a Supervised Arm interval that is less than the detector's supervision time.
9.3.4.
Instant Arming
Instant arming is a feature that allows you to cancel the entry delay after arming the system – see p. 18, 3.7.2 Instant
Arming. The feature is designed for use in situations where the system's perimeter is armed and nobody is expected to
enter the premises from outside during the armed period.
To enable/disable the Instant Arm option:
1.
From the Programming menu, select System Options, Arm/Disarm, Instant Arming [94034].
2.
Select Enabled or Disabled.
9.3.5.
Keyfob Disarm
The Keyfob Disarm option enables you to determine whether it is possible for the user to disarm the system using their
keyfob at all times or during the entry delay only.
This feature can be applied only after the system has been fully armed.
1.
From the Programming menu, select System Options, Arm/Disarm, KF Disarm [94035].
2.
Select Always or On Entry.
9.3.6.
Supervised Arm Mode
For the Supervised Arm option, you can choose whether the Control System waits for a transmission of all the devices
included in this supervision, or from at least one of them – see p. 47, 9.3.3 Supervised Arm.
To program the Supervised Arm mode:
1.
From the Programming menu, select System Options, Arm/Disarm, Super Arm Mode [94036].
2.
Select All Reg. Devices or Any Reg. Devices.
9.4.

Panic Alarm

SOS Panic alarms generated from the front panel, keypads or keyfobs can be defined as either audible or silent.
To program the Panic Alarm setting:
1.
From the Programming menu, select System Options, Panic Alarm [9404].
2.
Select Audible or Silent.