Description
Temperature
Temp./Humidity Cycle
Dry heat
EMC/CE Testing
Electro-Static Discharge Test
Condition
Perform a standard charge and fast
discharge at 0°C, 25°C and 40°C and
measured the time taken for a fast dis-
charge at 25°C.
After standard charge, carry out 5
cycles of the following: 65°C and
90% humidity for 8 hrs.
25°C and 65% humidity for 4 hrs.
-20°C for 8 hrs. 25°C and 65%
humidity for 4 hrs.
Following that, perform a fast dis-
charge, standard charge and then a
fast discharge. Measure the time
taken for the second discharge.
After standard charge, keep the
battery at 60°C for 8 hrs. Carry out a
fast discharge, standard charge and
then a fast discharge. Measure the
time taken for the second discharge.
The battery will need to pass the
requirements of the EMC directive
89/336/EEC (and amendments) when
fitted into the product:
Emissions to EN55022 Class B
(1998) Immunity to EN55024 (1998)
EN61000-4-8:
A. Contact Discharge: +/-8kV for
each contact pad by 10 times.
B. Air Discharge: +/-15kV for 10
times (the discharge test point is for
around battery casing.)
3
WORKABOUT PRO
Chapter 8: Specifications
Super High-Capacity (Model WA3010)
100 mins. @ 0°C
110 mins. @ 23°C
105 mins. @ 40°C
100 minutes or more
100 minutes or more
Test to be performed
by manufacturer.
No damage
with Windows Mobile 6.1 User Manual
Standard
305