Decoded (Internal) Scanner; Options –- Decoded (Internal) Scanner - Psion Teklogix 7527C-G2 User Manual

Hand-held computer
Table of Contents

Advertisement

Appendix D: Bar Code Settings

Decoded (Internal) Scanner

D.2
Decoded (Internal) Scanner
D.2.1
Options –– Decoded (Internal) Scanner
Dot Time (msec)
The value selected for “"Dot Time (msec)”" determines (in milliseconds) how long the target-
ing dot remains on before the scanner switches to a normal scan sweep. When you double-
tap on this parameter, a dialog box is displayed in which you can enter a value of 0 msec,
200 msec or 400 msec. A value of 0 (zero) disables the target dot.
Aim Duration
This parameter determines the total time the aiming pattern appears before the scanner laser
begins sweeping. When you double-tap on this parameter, a dialog box is displayed in which
you can enter a value from 0 to 30 (0 to 3 sec.). A value of 0 (zero) disables the aiming dot.
Laser On Time
The value assigned to this parameter determines how long the laser will remain on when the
scan button or trigger is pressed.
Double-tapping on this parameter displays a dialog box in which you can enter a value
between 5 and 99, each number representing 0.1.