Appendix D: Bar Code Settings
Discrete 2 of 5
D.3.18 Discrete 2 of 5
Enabled
Set this parameter to on to enable “"Discrete 2 of 5”".
Minimum And Maximum Length
The length of a code refers to the number of characters (i.e., human readable characters), in-
cluding check digit(s). Double-tapping on these parameters displays a screen in which you
can set the minimum and maximum allowable code lengths –– 1 to 48.
Length Restriction
Refer to “"Length Restriction”" on page D-8 for details.
Add/Remove Data
Refer to “"Add/Remove Data”" on page D-9 for details.
D.3.19 Telepen
Enabled
Set this parameter to on to enable “"Telepen”".
Output
If you choose AIM Output, the imager reads symbols with start/stop pattern 1 and decodes
them as standard full ASCII (start/stop pattern 1). If you choose Original Output, the imager
reads symbols with start/stop pattern 1 and decodes them as compressed numeric with op-
tional full ASCII (start/stop pattern 2).
Minimum And Maximum Length
The length of a code refers to the number of characters (i.e., human readable characters), in-
cluding check digit(s). Double-tapping on these parameters displays a screen in which you
can set the minimum and maximum allowable code lengths –– 1 to 60.
Length Restriction
Refer to “"Length Restriction”" on page D-8 for details.
Add/Remove Data
Refer to “"Add/Remove Data”" on page D-9 for details.