Psion Teklogix 7527C-G2 User Manual page 317

Hand-held computer
Table of Contents

Advertisement

Description
Temperature
Temp./Humidity Cycle
Dry heat
EMC/CE Testing
Electro-Static Discharge
Test
Condition
Perform a standard charge and fast dis-
charge at 0°C, 25°C and 40°C and
measured the time taken for a fast dis-
charge at 25°C.
After standard charge, carry out 5
cycles of the following: 65°C and 90%
humidity for 8 hrs.
25°C and 65% humidity for 4 hrs.
-20°C for 8 hrs. 25°C and 65% humid-
ity for 4 hrs.
Following that, perform a fast dis-
charge, standard charge and then a fast
discharge. Measure the time taken for
the second discharge.
After standard charge, keep the battery
at 60°C for 8 hrs. Carry out a fast dis-
charge, standard charge and then a fast
discharge, measured the time taken for
the second discharge.
The battery will need to pass the
requirements of the EMC directive
89/336/EEC (and amendments) when
fitted into the product:
Emissions to EN55022 Class B (1998)
Immunity to EN55024 (1998)
EN61000-4-8:
A. Contact Discharge: +/-8kV for each
contact pad by 10 times.
B. Air Discharge: +/-15kV for 10 times
(the discharge test point is for around
battery casing.)
WORKABOUT PRO
Chapter 8: Specifications
High-Capacity (Model WA3006)
100 mins. @ 0°C
110 mins. @ 23°C
105 mins. @ 40°C
100 minutes or more
100 minutes or more
Test to be performed
by manufacturer.
No damage
3
with Windows Mobile 6.1 User Manual
Test Result
299

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents