Appendix D: Bar Code Settings
Code 93
D.4.10
Code 93
Enabled
Set this parameter to on to enable “"Code 93”".
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to
the number of characters (i.e., human readable characters), including
check digit(s).
Length Restriction
Refer to “"Length Restriction”" on page D-8 for details.
Add/Remove Data
Refer to “"Add/Remove Data”" on page D-9 for details.
D.4.11

Codabar

Enabled
Set this parameter to on to enable “"Codabar”".
Start/Stop Transmit
Codabar can use the following sets of characters as start and stop characters:
a, b, c, d
A, B, C, D
a, b, c, d, /, t, n, *, e
DC1, DC2, DC3, DC4
Thus, when a set is chosen, the first and last digits of a Codabar message must be one of
those characters and the body of the message should not contain these characters. Setting
this parameter to Not Transmitted strips the start and stop characters from this bar code.
CLSI Library System
When enabled, spaces are inserted after characters 1, 5, 10 in the 14-character label (used in
the USA by libraries using the CLSI system).