D.3.13 MSI Plessey
Enabled
Set this parameter to on to enable MSI.
Enable Plessey
Set this parameter to on to enable Plessey.
Check Char
When this parameter is set to Validate only, the integrity of the symbol is checked to ensure
that it complies with specified algorithms.
If “"Check Char”" is set to Validate and Transmit, the check character is validated and trans-
mitted with the data.
Setting this parameter to None disables this function.
Minimum And Maximum Length
These parameters apply to MSI bar codes. The length of a code refers to the number of char-
acters (i.e., human readable characters), including check digit(s). Double-tapping on these
parameters displays a screen in which you can set the minimum and maximum allowable
code lengths –– 4 to 48.
Plessey Minimum And Plessey Maximum Length
These parameters apply to Plessey bar codes.The length of a code refers to the number of
characters (i.e., human readable characters), including check digit(s). Double-tapping on
these parameters displays a screen in which you can set the minimum and maximum allow-
able code lengths –– 4 to 48.
Length Restriction
Refer to “"Length Restriction”" on page D-8 for details.
Add/Remove Data
Refer to “"Add/Remove Data”" on page D-9 for details.
D.3.14 Code 11
Enabled
Set this parameter to on to enable “"Code 11”".
3
WORKABOUT PRO
with Windows Mobile 6.1 User Manual
Appendix D: Bar Code Settings

MSI Plessey

D-29