8.3.1.5 Environmental Test
Description
Drop
Storage at high temp.
Storage at low temp.
Storage at high temp.
and high humidity
Storage temp.
cycling
Vibration resistance
Impact shock resist-
ance
ESD protection
Test Reference
(mechanical)
EN60068-2-2 Test
EN60068-2-1 Test
IEC68-2-3 Test
IEC68-2-14 Test
BS2011 Part 2.1
FDC (IEC68-2-37)
-
-
WORKABOUT PRO
High-Capacity (Model WA3006)
Test Condition/Result
Drop sample battery on all faces from height of
1.2 meters onto concrete floor.
No explosion, fire, vent, leakage and the open
circuit voltage higher than 3.7V.
+60°C dry for 240 hours
No explosion, fire, vent or leakage.
-20°C dry for 240 hours
No explosion, fire, vent or leakage.
+40°C at 90%RH for 240 hours.
No explosion, fire, vent or leakage.
+60oC (2C) for 1 hour (T1), -20oC (2C) for 1
hour. 3 minutes Max allowed for change
between T1 and T2.
Cycle 10 times
No explosion, no fire, no vent, and no leakage.
After standard charge, tested under the follow-
ing conditions: Random vibration 5Hz-500Hz
ASD 0.02g2/Hz in 3 axis for 15 mins. After
which, carry out a standard discharge, charge,
discharge. No parting joints/cracks or damage to
connectors. No leakage or critical damage.
3 cycles of 50G 11ms, 1/2 sine pulse accelera-
tion applied in 6 directions. 18 shocks total.
Accordance with EN61000-4-8
3
with Windows Mobile 6.1 User Manual
Chapter 8: Specifications
301