4. Connect test equipment and, with transmission in
neutral, turn engine over until voltage stabilizes.
Note read.ings.
5. Current draw should be between 90-130 amperes.
STARTER
Starter R&~moval
1. Dixon&t starter wiring.
2. Remove starter support bracket.
3. Removk two starter bolts, one nut and lockwash-
4.
Starter Di+assembly
1. Hold starter in a vise, as shown in Figure lB- 3.
Mark end' frame and field frame to ensure correct
Figure 1 B-3 Cranking Motor in Vise
2. Remove both starter through bolts and field coil
end from solenoid switch lower threaded bolt. See
Figure lB13.
STARTING
3. Remove end frame from field frame and pull both
insulating tubes out of field frame.
To prevent brushes from coming out when remov-
4.
ing the field frame, place a 29 millimeter socket over
commutator while lifting up on the field frame. The
brushes will be held in place
Figure 18-4 Removing Field Frame
5. Remove the two (2) solenoid attaching screws and
remove solenoid and spring.
Figure lb5 Driving Retaining Ring Back
SYSTEM
by
the socket. See Figure