Cinema Projector Menus
Table 6.4 Summary of Status: System Components
All
Displays all the status items that are in
alarm state.
Cooling
Cooling Pump
Card Cage Fanpack (bottom right)
Card Cage Fanpack (top right)
Intake Fanpack (bottom right)
Intake Fanpack (bottom left)
Intake Fanpack (top right)
Intake Fanpack (top left)
LAD Fan
Radiator
Card Cage Exhaust (Operator side)
Card Cage Exhaust (Non-Operator side)
Lamp Power Supply Fan
Temperatures (degrees Celsius)
Card Cage Exhaust
Lamp Exhaust
Filtered Air Intake
Integrator
Prism
Blue DMD
Green DMD
Red DMD
ILS Board
LampLOC™ Board
EVB Board
Lamp Power Supply
FMT FPGA
ICP FPGA
ICP Board
PIB
Backplane
Interlocks
Extractor fan intake
AC Blower
Lamp Door
Fire Alarm
Signal
Input Frequency
Input Port
Data Format
LD Link0 State
LD Link1 State
LD Link2 State
LD Link3 State
Health
292-A Total SMPTE Error Count
292-A Recent SMPTE Error Count
292-B Total SMPTE Error Count
292-B Recent SMPTE Error Count
CPLD Self Test
PI Board Seated Properly
RAM Self Test
Flash Self Test
LVDS Self Test
LampLOC™ Main Code - CRC
LampLOC™ State
LampLOC™ X Sensor
LampLOC™ Y Sensor
LampLOC™ Z Sensor
6-8
65 °C = warning,
75 °C = critical
90 °C = warning,
100 °C = critical
60 °C = warning,
70 °C = critical
63 °C = warning,
68 °C = critical
63 °C = warning,
68 °C = critical
63 °C = warning,
68 °C = critical
OK/Failed
OK/Failed
OK/Failed
OK/Failed
CP2230 User Manual
020-100430-07 Rev. 1 (05-2014)