Time/Date (TMD)
Set/get the time, date and time zone.
SUBCODE
DESCRIPTION OF USE
DATE
Get the date in the form yyyy/mm/dd. Read-only.
DSTA
Set/get the daylight savings time adjust value.
TIME
Set/get the local time in the form hh:mm:ss. Ready only.
TOFF
Set Time Offset in seconds (± 900 seconds). Must be powered ON. (Write-only)
ZONE
Set/get the time zone
EXAMPLES:
(TMD+DSTA?) 0 or 1 (DST OFF or DST ON)
(TMD+DSTA 0) Turn daylight savings OFF (0) or ON (1)
(TMD+ZONE 20) Set time zone to EST
(TMD+TIME? ) Get local time (TMD+TIME! 17:50:45)
(TMD+TOFF 120) Increase the time by two minutes.
("TMD+TOFF: Disabled Control") Error message returned when power is OFF.
("TMD+TOFF: LD Real Time Clock Offset range for time adjustment has been exceeded.")
3D Output Reference Polarity (TOP)
Setup output timing signal reference polarity for 3D control.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid range is 101-164.
NONE
Select output reference polarity for the current channel.
EXAMPLES:
(TOP+C101 1) Set Output Reference Polarity to 1 on channel 101
(TOP+C101?) Get Output Reference Polarity on channel 101
User ID (UID)
Allows users to login to the serial interface.
SUBCODE
DESCRIPTION OF USE
NONE
None
EXAMPLES:
(UID "username" "password") Login a user
(UID) Logout the current user, also happens automatically when a new user logs in
(UID?) Display the current logged in user and their access level