• Perform a white test pattern. This is recommended to allow you to view LampLOC
To automatically adjust LampLOC
1. Tap Menu > Advanced Setup > LampLOC™ Setup.
2. Tap Do Auto.
5.5.4 Manually Adjust the Lamp Position
1. On the Main screen of the TPC, tap the test patterns button.
2. Tap RGB-12bit-Full Screen White.
3. Mount a light meter on a tripod and center it with the lens. The distance from the lens does not matter. You
may need an attenuator or an internal foil aperture.
4. Tap Menu > Advanced Setup > LampLOC™ Setup.
5. Tap the directional arrows to adjust the value displayed in the Z field. The brightness reading in front of
the lens should be maximized.
6. Tap the directional arrows to adjust the values displayed in the X and Y fields. The brightness reading in
front of the lens should be maximized.
7. Repeat Steps 5-6, but take your readings at the screen instead of at the lens.
8. Run LiteLOC™ or LampLOC™ if required.
5.5.5 View Lamp Information
To view information on the lamps previously installed in the cinema projector, or to add a new lamp:
Tap Menu > Advanced Setup > Lamp History.
5.5.6 Receive an Alarm when a Lamp Reaches Its Expiry Date
To receive an alarm when the lamp reaches its operational limit:
1. Tap Menu > Administrator Setup > Preferences.
2. Tap Lamp Expiry in the Alarm Triggers area.
5.5.7 Receive an Alarm when a Lamp Needs to be Rotated
To receive an alarm when the lamp reaches its operational limit:
1. Tap Menu > Administrator Setup > Preferences.
2. Tap Lamp Rotation in the Alarm Triggers area.
CP2230 User Manual
020-100430-07 Rev. 1 (05-2014)
:
™
Operation
progress on-screen.
™
5-3