Product Checking And Parts Identification - Mitsubishi Electric FR-F700 Series Instruction Manual

Fr-f700 series
Hide thumbs Also See for FR-F700 Series:
Table of Contents

Advertisement

1 PRODUCT CHECKING AND PARTS IDENTIFICATION

Unpack the inverter and check the capacity plate on the front cover and the rating plate on the inverter side face to
ensure that the product agrees with your order and the inverter is intact.
• Inverter Type
FR -
F740
Symbol
Voltage Class
F720
Three-phase 200V class
F740
Three-phase 400V class
RS-485 terminal
(Refer to page 23)
Connector for plug-in option connection
(Refer to the instruction manual of options.)
(Refer to page 24)
AU/PTC switchover switch
(Refer to the Instruction Manual (applied).)
Connector with/without EMC filter
(Refer to page 23)
Operation panel (FR-DU07)
(Refer to page 4)
Power lamp
Lit when the control circuit
(R1/L11, S1/L21) is supplied
with power.
ALARM lamp
Lit when the inverter is
in the alarm status
(major fault).
Front cover
(Refer to page 4)
Capacity plate
Capacity plate
Inverter type
REMARKS
For removal and reinstallation of covers, refer to page 4.
00126
- NA
-
Symbol
200V class
400V class
00046
00023
to
to
02330
03610
FR-F740-00126-NA
Serial number
Rated Inverter Current
Displays the rated current
PU connector
(Refer to page 23)
Main circuit
terminal block
(Refer to page 9)
Control circuit
terminal block
(Refer to page 16)
Wiring cover
(Refer to page 6)
Rating plate
Rating plate
Inverter type
Input rating
Output rating
Serial number
Overload Current Rating Ambient Temperature
LD
120% 60s, 150% 3s
SLD
110% 60s, 120% 3s
Cooling fan
(Refer to page 84)
Charge lamp
Lit when power
is supplied to
the main circuit
(Refer to page 9)
FR-F740-00126-NA
LD (50 C) XXA
SLD (40 C) XXA
50 C (122 F)
40 C (104 F)
1
1

Hide quick links:

Advertisement

Table of Contents
loading