Drive The Motor; Step Of Operation - Mitsubishi Electric FR-F700 Series Instruction Manual

Fr-f700 series
Hide thumbs Also See for FR-F700 Series:
Table of Contents

Advertisement

3 DRIVE THE MOTOR

3.1 Step of operation

The inverter needs frequency command and start command.
Refer to the flow chart below to perform setting.
Start command with
on the operation panel (PU)
How to
give a frequency
command?
Set from the
Change frequency
with ON/OFF switches
PU (FR-DU07/
connected to terminals
FR-PU04).
(multi-speed setting)
(PU)
{Refer to page 34}
{Refer to page 36}
CAUTION
Check the following items before powering on the inverter.
· Check that the inverter is installed correctly in a correct place. (Refer to page 6)
· Check that wiring is correct. (Refer to page 8)
· Check that no load is connected to the motor.
·When protecting the motor from overheat by the inverter, set Pr.9 Electronic thermal O/L relay (Refer
to page 32)
·
When the rated frequency of the motor is 50Hz, set Pr.3 Base frequency (Refer to page 33)
Step of operation
Step of operation
Installation/mounting
Wiring of the power
supply and motor
System examination
to give a start
command?
Perform frequency
setting by a current
output device
(Connection across
terminals 4-5)
(External)
(External)
{Refer to page 40}
Change of frequency
Set from the
with ON/OFF switches
PU (FR-DU07/
connected to terminals
FR-PU04).
(multi-speed setting)
(PU)
{Refer to page 42}
f op
{Refer to page 6}
{Refer to page 9}
Start command using the PU connector and
How
RS-485 terminal of the inverter and plug-in
option (Communication)
Refer to the Instruction Manual (applied).
Connect a switch, relay, etc.
to the control circuit
terminal block of the inverter
to give a start command. (External)
Perform frequency
setting by a voltage
output device
(Connection across
terminals 2-5)
(External)
{Refer to page 38}
Perform frequency
setting by a current
output device
(Connection across
terminals 4-5)
(External)
(External)
{Refer to page 44}
{Refer to page 48}
Step of operation
How to
give a frequency
command?
Perform frequency
setting by a voltage
output device
(Connection across
terminals 2-5)
(External)
{Refer to page 46}
27
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents