Product Checking And Parts Identification; Outline Dimension Drawings - Mitsubishi Electric D700 Quick Start Manual

Table of Contents

Advertisement

FR-D710W-042
FR-D720-070 or more
FR-D740-012 or more
FR-D720S-070, 100
Front cover
NOTE
• When encasing multiple inverters, install them in parallel as a
cooling measure.
• When using the inverters at the surrounding air temperature of 40°C
(104°F) or less, the inverters can be installed without any clearance
between them (0cm (0 inches) clearance). When surrounding
air temperature exceeds 40°C (104°F), clearances between the
inverters should be 1cm (0.39 inches) or more (5cm (1.96 inches) or
more for the FR-D720-238 and FR-D740-120, or more).
• Install the inverter vertically.
10cm(3.94inches)
or more
10cm(3.94inches)
or more

2.1 PRODUCT CHECKING AND PARTS IDENTIFICATION

n GENERAL PRECAUTION
The bus capacitor discharge time is 10 minutes. Before starting wiring
or inspection, switch power off, wait for more than 10 minutes, and
check for residual voltage between terminal P/+ and N/- with a meter
etc., to avoid a hazard of electrical shock.
n ENVIRONMENT
Before installation, check that the environment meets following
specifications.
-10°C to +50°C
Surrounding Air
(14°F to 122°F)
Temperature
(non-freezing)
Ambient Humidity 90% RH maximum
Storage
-20°C to +65°C (-4°F to 149°F) (Temperature applicable for a
Temperature
short time, e.g. in transit.)
Indoors (free from corrosive gas, flammable gas, oil mist, dust
Ambience
and dirt)
Maximum 1000m (3280.80 feet) above sea level for standard
operation. After that derate by 3% for every extra 500m (1640.40
Altitude, Vibration
feet) up to 2500m (8202 feet) (91%).
5.9m/s² or less
MitsubishiElectric Automation, Inc.
Wiring cover
Measurement
position
Inverter
5cm
5cm
(1.97 inches)
(1.97 inches)
5cm
Measurement
(1.97 inches)
position
NOTE
• Install the inverter on a strong surface securely and vertically with
bolts.
• Leave enough clearances and take cooling measures.
• Avoid places where the inverter is subjected to direct sunlight, high
temperature and high humidity.
• Install the inverter on a non-combustible wall surface.

3. OUTLINE DIMENSION DRAWINGS

W1
W
Single-phase 110V class
Inverter Type
W
W1
FR-D710W-008
FR-D710W-014
68 (2.68)
56 (2.20)
FR-D710W-025
FR-D710W-042 108 (4.25)
96 (3.78)
Three-phase 200V class
Inverter Type
W
W1
FR-D720-008
FR-D720-014
68 (2.68)
56 (2.20)
FR-D720-025
FR-D720-042
FR-D720-070
108 (4.25)
96 (3.78)
FR-D720-100
FR-D720-165
170 (6.69)
158 (6.22)
FR-D720-238
220 (8.66)
208 (8.19)
FR-D720-318
Three-phase 400V class
Inverter Type
W
W1
FR-D740-012
FR-D740-022
FR-D740-036
108 (4.25)
96 (3.78)
FR-D740-050
FR-D740-080
FR-D740-120
220 (8.66)
208 (8.19)
FR-D740-160
Three-phase 200V class
Inverter Type
W
W1
FR-D720S-008
FR-D720S-014
68 (2.68)
56 (2.20)
FR-D720S-025
FR-D720S-042
FR-D720S-070
108 (4.25)
96 (3.78)
FR-D720S-100
140 (5.51)
128 (5.04)
D700 QUICK START MANUAL
D
(Unit:mm (inches))
H
H1
D
80.5 (3.17)
110.5 (4.35)
128 (5.04)
118 (4.65)
142.5( 5.61)
149.5 (5.89)
H
H1
D
80.5 (3.17)
112.5 (4.43)
128 (5.04)
118 (4.65)
132.5 (5.22)
135.5 (5.34)
142.5( 5.61)
150 (5.91)
138 (5.43)
155 (6.10)
H
H1
D
129.5 (5.10)
128 (5.04)
118 (4.65)
135.5 (5.34)
155.5 (6.12)
165.5 (6.52)
150 (5.91)
138 (5.43)
155 (6.10)
H
H1
D
80.5 (3.17)
128 (5.04)
118 (4.65)
142.5 (5.61)
162.5 (6.40)
155.5 (6.12)
150 (5.91)
138 (5.43)
145 (5.71)