Extended parametersExtended parameters
Parameter
Name
Operation mode
79
selection
Communication
startup mode
340
selection
Motor capacity
80
(simple magnetic
flux vector control)
90
Motor constant (R1)
V/F1
100
(first frequency)
V/F1 (first
101
frequency voltage)
V/F2
102
(second frequency)
V/F2 (second
103
frequency voltage)
V/F3
104
(third frequency)
V/F3 (third
105
frequency voltage)
V/F4
106
(fourth frequency)
V/F4 (fourth
107
frequency voltage)
V/F5
108
(fifth frequency)
V/F5 (fifth
109
frequency voltage)
Refer to page 108.
71
110
Incre
Initial
Range
ments
Value
0
External/PU switchover mode
1
Fixed to PU operation mode
2
Fixed to External operation mode
3
External/PU combined operation mode 1
1
0
4
External/PU combined operation mode 2
6
Switchover mode
External operation mode (PU operation
7
interlock)
0
As set in Pr.79.
Started in the network operation mode.
When the setting is "2", it will resume the pre-
1, 2
instantaneous power failure operation mode
after an instantaneous power failure occurs.
Started in the network operation mode.
1
0
Operation mode can be changed between
the PU operation mode and network
10, 12
operation mode from the operation panel.
When the setting is "12", it will resume the pre-
instantaneous power failure operation mode
after an instantaneous power failure occurs.
To select the simple magnetic flux vector
control, set the capacity of the motor
0.4 to 55/
used.
0.01kW/
0 to 3600kW
0.1kW
9999
*13 The setting depends on the inverter
*13
*13
9999
V/F control is performed
Used to set the motor primary resistance
value.
0 to 50Ω/
(Normally setting is not necessary.)
0 to 400mΩ
*14 The setting depends on the inverter
0.001Ω/
9999
*14
0.01mΩ*
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA) constants
0 to 400Hz,
0.01Hz
9999
9999
0.1V
0V
0 to 1000V
0 to 400Hz,
0.01Hz
9999
9999
0.1V
0V
0 to 1000V
0 to 400Hz,
0.01Hz
9999
Set each points (frequency, voltage) of V/
9999
F pattern.
9999: No V/F setting
0.1V
0V
0 to 1000V
0 to 400Hz,
0.01Hz
9999
9999
0.1V
0V
0 to 1000V
0 to 400Hz,
0.01Hz
9999
9999
0.1V
0V
0 to 1000V
Description
capacity (200V class and FR-F740-
01160 or less/FR-F740-01800 or more)
capacity (200V class and FR-F740-
01160 or less/FR-F740-01800 or more)
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
×