Output frequency, motor current (steady or peak value), output voltage, alarm indication,
frequency setting, running speed, converter output voltage (steady or peak value), electronic
thermal relay function load factor, input power, output power, load meter, cumulative energization
time, actual operation time, motor load factor, cumulative power, power saving effect, cumulative
saving power, regenerative brake duty
value, inverter I/O terminal monitor, input terminal option monitor
monitor
, option fitting status monitor
*1
Alarm definition is displayed during the protective function is activated, output voltage/
current/frequency/cumulative energization time and eight past alarm definition is stored.
Operation guide/trouble shooting with a help function
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during
deceleration, overvoltage during acceleration, overvoltage during constant speed, overvoltage
during deceleration, inverter protection thermal operation, motor protection thermal operation,
heatsink overheat, instantaneous power failure occurrence, undervoltage, input phase failure,
motor overload, output side ground fault overcurrent, output phase failure, external thermal
relay operation, PTC thermistor operation, option alarm, parameter error, PU disconnection,
retry count excess, CPU alarm, operation panel power supply short circuit, 24VDC power
output short circuit, output current detection value excess, inrush resistance overheat,
communication alarm (inverter), analog input alarm, internal circuit error (15V power supply),
fan fault, overcurrent stall prevention, overvoltage stall prevention, electronic thermal relay
function prealarm, PU stop, maintenance timer alarm
parameter write error, copy operation error, operation panel lock, parameter copy
-10°C to +50°C(14°F to 122°F) (non-freezing)
-10°C to +40°C(14°F to 104°F) (non-freezing)
90%RH or less (non-condensing)
-20°C to +65°C (-4°F to +149°F)
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Maximum 1000m (3280.80 feet) above sea level for standard operation. After that derate by
3% for every extra 500m (1640.40 feet) up to 2500m (8202.10 feet) (92%) 5.9m/s
(conforming to JIS C 60068-2-6)
Common specifications
, PID set point, PID measured value, PID deviation
*4
, output terminal option
*1
, terminal assignment status
*2
*2
*2
, brake transistor alarm detection
*1
,
*4
2
or less
7
93