ENTER/EXIT PROGRAMMING MODE
MSI — cont.
MSI Minimum Reads
This feature specifies the minimum number of consecutive times an MSI label must be decoded
before it is accepted as good read.
$CMSMR02
MSI Minimum Reads = 2
$CMSMR04
MSI Minimum Reads = 4
Product Reference Guide
$CMSMR01
MSI Minimum Reads = 1
$CMSMR03
MSI Minimum Reads = 3
DEFAULT
MSI
217