Transmitter Rf Power - Tait TM8100 mobiles Service Manual

Hide thumbs Also See for TM8100 mobiles:
Table of Contents

Advertisement

12.2

Transmitter RF Power

Introduction
Table 12.3 Voltages in millivolts corresponding to nominal forward and reverse powers
Frequency band
A4
B1
C0
D1
H5
H6
350
Transmitter Fault Finding (25W)
If there is no fault with the power supplies, check the transmitter RF power
and correct any fault. The procedure is covered in the following eight tasks:
Task
4: check forward and reverse powers
Task
5: check RF output power
Task
6: power unchanged regardless of setting
Task
7: check for inhibiting of transmitter
Task
8: check temperature sensor
Task
9: power and current are skewed
Task
10: repair output matching circuitry
Task
11: power and current are low
The measurement points for diagnosing faults concerning the transmitter
RF power are summarized in
(checking the forward and reverse powers) are supplied in
Forward power (318 command)
2700 to 3900
1100 to 2000
1100 to 2000
1600 to 2500
2500 to 3500
2800 to 3900
Figure
12.5. Data required for the first task
Reverse power (319 command)
<700
<500
<500
<700
<1000
<1000