Tait TM8100 mobiles Service Manual page 160

Hide thumbs Also See for TM8100 mobiles:
Table of Contents

Advertisement

Task 8 —
Check
Error Messages
Table 6.1
Error messages
Error message
Error E0001
Unknown
Error E0002
Unknown
Error E0003
Corrupt FW
Error E0008
System error
0xabcdefgh
Temperature threshold
exceeded
Cannot tx
Out of lock
Programming mode,
invalid radio ...
160
Servicing Procedures
4.
If there is a fault in the user interface, repair the radio as described in
"Fault Finding of Control Head with Graphical Display" on
page 423
or
"Fault Finding of Control Head with 1-, 2- or 3-
Digit Display" on page
5.
If there is no fault, go to
The radio may display an error message. Carry out the corrective actions
described in
Table
6.1.
Corrective action
Turn the radio off and then back on.
Continue with servicing tasks to locate the problem.
Re-download the radio's firmware.
Turn the radio off and then back on. If the system error persists, download new
radio firmware.
To capture details of the system error, use CCTM command
Wait until the radio has cooled down.
Go to
Task 9 on page
161.
Go to
"Frequency Synthesizer Fault Finding" on page 185.
Re-program the radio with a new programming database. If the problem persists,
update or reload the radio's firmware, and re-program the radio's calibration
database.
447.