Section 3: Operation
8. Run LiteLOC™ or LampLOC™ if required.
5.5.5 View Lamp Information
To view information on the lamps previously installed in the projector, or to add a new lamp:
Tap Menu > Advanced Setup > Lamp History.
5.5.6 Receive an Alarm when a Lamp Reaches Its Expiry Date
To receive an alarm when the lamp reaches its operational limit:
1. Tap Menu > Administrator Setup > Preferences.
2. Tap Lamp Expiry in the Alarm Triggers area.
5.5.7 Receive an Alarm when a Lamp Needs to be Rotated
To receive an alarm when the lamp reaches its operational limit:
1. Tap Menu > Administrator Setup > Preferences.
2. Tap Lamp Rotation in the Alarm Triggers area.
5.5.8 Lamp Expiry Hours
This table lists the maximum hours projector lamps can operate before replacement:
Table 5.3 Lamp Expiry Hours
Lamp Type
CXL-14 (1.4 kW)
CDXL-18SD (1.8 kW)
CDXL-20SD (2.0 kW)
5.5.9 Minimum and Maximum Lamp Power Ratings
This table lists the minimum and maximum power settings for projector lamps:
Table 5.4 Minimum and Maximum Lamp Power by Lamp Type
Lamp Type
CXL-14M
CXL-16M
CDXL-18SD
CDXL-20SD
5-4
Replace BEFORE
3000 hours
1500 hours
1500 hours
Lamp Size
Min Lamp Power
1.4 kW
1000W (70)%
1.6 kW
1000W (62)%
1.8 kW
1000W (56%)
2 kW
1000W (50%)
Max Lamp Power
1575W (110%)
1760W (110%)
1980W (110%)
2100W (105%)
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)