Advertisement

Section 6: Projector Menus

6.13.2 Config 2 Window

Use the Channel Setup: Config 2 window to change the color settings of a channel.
Table 6.9 Config 2 Window
Control
1: Measured Color
2: Target Color*
3: Color Space*
4: Gamma*
5: LUT_CLUT*
6: Scan Type
7: Automatic Scan
Type Detection
8: LD Bypass
* NOTE: Components marked with an asterisk (*) are part of pre-defined PCFs (Projector Configuration Files) that controls image
processing for a given source. When you select Use PCF, these options are not available.
6-20
1
2
3
4
5
Figure 6-14 Channel Setup: Config 2 Window
Description
The Measured Color Gamut Data (MCGD) file to use as a reference for calculating target color
processing.
The Target Color Gamut Data (TCGD) value.
The method of color decoding for the current source. The default is YCbCr for all DVI sources. The
default for all cinema sources is Unity RGB.
The gamma correction required for the proper tonal range of the source material.
Applies a 3D color cube for increased color accuracy.
The video scan type. The default is Progressive.
Automatically performs scan type detection. This feature is supported for PIB inputs only.
Bypasses the link decrypter. Select this option only if Marriage is broken and the content being displayed
is not CineLink 2 encrypted.
6
7
8
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)