Return total failed lamp strikes on the installed lamp
FLSK
Return total failed lamp restrikes on the installed lamp
FRSK
Return total lamp unexpected off times on the installed lamp
LPOF
Return lamp usage for current lamp in hours.
NONE
Return total lamp strikes on the installed lamp
TLSK
EXAMPLES:
(LPH?) Get usage in hours
(LPH+FLSK?) Get lamp strikes
Lamp Intensity (LPI)
Set lamp intensity setpoint. The value is used when lamp mode is set to LiteLOC™. The projector will adjust the
Lamp Power to maintain this intensity. NOTE: This command can only be used to update the current lamp file.
Changing the lamp intensity for the current channel will change the lamp intensity for any channel using the same
lamp file.
SUBCODE
DESCRIPTION OF USE
Replace Cxxx with the channel number. Valid range is 101-164.
Cxxx
Set lamp intensity for the current channel.
NONE
EXAMPLES:
(LPI 4500) Set lamp intensity to 4500 for current channel
(LPI+C103 4000) Set the lamp intensity to 4000 for channel 3
(LPI?) Get lamp intensity for the active channel
Lamp Life (LPL)
Set/get expected lamp life in hours. The default hours will be used if lamp life is 'not set'. message will be sent out
when lamp usage is over the lamp life.
SUBCODE
DESCRIPTION OF USE
0 - No warning will be generated.
LIFE
1 - Lamp Life Expiry Warning will be generated when lamp hours extends past lamp life. Warning will be
reported in SST. Warning will be cleared by extending lamp life or changing the lamp.
Set or get expected lamp life.
NONE
Set to 1 acknowledge the Lamp Rotation Warning. Will auto clear at lamp life or on lamp change.
ROTA
0 - No warning will be generated.
ROTW
1 - Lamp Rotation Warning will be generated when lamp hours extends past 1/2 lamp life. Warning will be
reported in SST. Warning will be cleared by LPL+ROTA or changing the lamp.
EXAMPLES:
(LPL 1500) Set lamp life limit to 500 hours.
(LPL 0) Set lamp life limit to default hours based on the lamp type.
(LPL ?) Get lamp life limit.
(LPL+LIFE 1) Enable lamp expired message.
(LPL+LIFE 0) Disable lamp expired message.
(LPL+ROTW 1) Enable lamp rotation message.
(LPL+ROTA 1) Acknowledge that lamp was rotated.
Lamp Mode (LPM)
Set lamp mode to constant power or LiteLOC™ for global and per channel. NOTE: This command can only be
used to update the current lamp file. Changing the lamp power for the current channel will change the lamp power
for any channel using the same lamp file.
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)
Appendix A: Serial API Commands
A-13