Appendix A: Serial API Commands
System Status (SST)
etrieve the various system status groups.
R
SUBCODE
DESCRIPTION OF USE
Returns a summary of any active alarms
ALRM
Returns configuration data - model, sn, build date, etc
CONF
Returns cooling data - cooling fans, air flow, etc
COOL
Returns system health
HLTH
Returns interlock data
INTE
Returns lamp operational data.
LAMP
Returns information on all status groups, with one message per item.
NONE
Returns peripherals data - Cine-IPM, etc
PERI
Returns security data
SECU
Return serial numbers
SERI
Returns signal data - freq, etc.
SIGN
Returns system data - power, hours of use, shutter open, etc
SYST
Returns temperature data
TEMP
Returns version numbers
VERS
EXAMPLE:
(SST+ALRM?) returns (SST+ALRM!000 002 "101" "Prism temperature") where parameters are:
P1=index number,
P2=error level,
P3=value,
P4=description.
Error level is:
0=no errors or warnings,
1=warning,
2=error,
3=error and warning
Stop DLP Communication (STP)
Stop communications to DLP
SUBCODE
DESCRIPTION OF USE
0 - restart DLP communications;
NONE
1 - stop DLP communications.
EXAMPLES:
(STP 0) Restart DLP communication
(STP 1) Stop DLP communication
(STP?) Request current state. Example response is (STP!000)
A-20
®
Cinema Electronics temporarily, i.e. for DLP software upgrading.
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)