Install Wide Converter Lens; Install Optional Motorized Auxiliary Lens Mount; Install Lamp - Christie CP 2210 User Manual

Hide thumbs Also See for CP 2210:
Table of Contents

Advertisement

5. Focus primary lens: With the anamorphic lens not in place, re-focus the primary lens. The goal is good
focus at center and on all sides. Now add the anamorphic lens and check focus again.
6. Focus anamorphic lens: If center-to-edge horizontal focus in the image needs improvement, focus the
anamorphic lens - rotate the focus barrel as needed.
2.9

Install Wide Converter Lens

1. Install the Auxiliary Lens Mount and WCL according to the instructions provided with the kit. Ensure the
primary lens is optimized first for best optical alignment, offset and boresight.
2. Image shift: Adjust the vertical and horizontal position of the WCL to align it with the already adjusted
prime lens.
3. Pitch Adjustment: Adjust pitch, either up or down to equalize the top and bottom clearance to the prime
lens barrel.
4. Yaw Adjustment: Adjust yaw so the clearance between both lens barrels is equal from side-to-side.

2.10 Install Optional Motorized Auxiliary Lens Mount

The M-MALM assembly is an optional hardware
component, which when needed can be used to
switch from flat to "scope" formats. This assembly
can be secured to the projector base and supports
either a 1.25x anamorphic lens or a 1.26x wide
converter lens (WCL). The drive and control
electronics package for this motorized accessory
lens mount communicates with and is controlled by
the projector over a 9-pin subminiature D cable
that connects to the User I/O panel. For details,
refer to the Motorized Auxiliary Lens Mount (M-
ALM) Installation Instruction Sheet (P/N: 020-
100188-xx).

2.11 Install Lamp

DANGER
• Only personnel trained specifically by Christie on lamp replacement and lamp safety may
handle the lamp. High-pressure lamp may explode if improperly handled.
• Always wear Christie approved protective safety clothing (P/N: 598900-095) whenever the
internal lamp door is open or while handling the lamp.
• Never attempt to access the lamp while the lamp is ON. Wait at least 15 minutes after the
lamp turns OFF before powering down, disconnecting from AC and opening the internal
lamp door.
changed). 2) DO NOT place heavy objects on the open rear access door.
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)
1) Auto LampLOC
must be run any time the lamp is removed (inspected or
Section 2: Installation and Setup
Figure 2-8 MALM Overview
2-9

Advertisement

Table of Contents
loading

Table of Contents